Difference between revisions of "Float Data Hourly"
| Line 1: | Line 1: | ||
| {| class="wikitable" | {| class="wikitable" | ||
| |+ Caption text | |+ Caption text | ||
| |- | |- | ||
| ! Name !! Description !! Comment | ! Name !! Type !!Description !! Comment | ||
| |-   | |-   | ||
| | CaseID || Case identifier ||   | | CaseID || Integer|| Case identifier ||   | ||
| |-   | |-   | ||
| | DataID || Reference  | | DataID || Reference ||  ||  | ||
| |-   | |-   | ||
| | Offset || Time in seconds after admission ||   | | Offset || Integer|| Time in seconds after admission ||   | ||
| |-   | |-   | ||
| | Val || Value ||   | | Val || Float || Value || The unit (if applicable) is found in d_references | ||
| |-   | |-   | ||
| | cnt || Amount of values aggregated ||   | | cnt || Integer || Amount of values aggregated ||   | ||
| |-   | |-   | ||
| | rawdata || List of 60 floats containing raw data  || Due to excessive storage needs minute values have been aggregated.   | | rawdata || Blob || List of 60 floats containing raw data  || Due to excessive storage needs minute values have been aggregated.   | ||
| |} | |} | ||
| Line 23: | Line 22: | ||
| Raw values are saved in field data_float_h.rawdata, being a list of bytes. (IEEE 754 Single(4 bytes), LittleEndian) | Raw values are saved in field data_float_h.rawdata, being a list of bytes. (IEEE 754 Single(4 bytes), LittleEndian) | ||
| <nowiki><noinclude> | |||
| The recommended way to access this data is using our provided software ([[Get Started]]). An example on how to deserialize the raw_data field can be found [[Deserialize Raw Data|here]]. | The recommended way to access this data is using our provided software ([[Get Started]]). An example on how to deserialize the raw_data field can be found [[Deserialize Raw Data|here]]. | ||
| </noinclude></nowiki> | |||
| Metavision does, in database, not differentiate between qualitative (i.e. blood pressure) and quantitative (i.e. drainage volume) data, this was done programatically saving the sum instead of average. | Metavision does, in database, not differentiate between qualitative (i.e. blood pressure) and quantitative (i.e. drainage volume) data, this was done programatically saving the sum instead of average. | ||
Revision as of 19:50, 31 October 2022
| Name | Type | Description | Comment | 
|---|---|---|---|
| CaseID | Integer | Case identifier | |
| DataID | Reference | ||
| Offset | Integer | Time in seconds after admission | |
| Val | Float | Value | The unit (if applicable) is found in d_references | 
| cnt | Integer | Amount of values aggregated | |
| rawdata | Blob | List of 60 floats containing raw data | Due to excessive storage needs minute values have been aggregated. | 
Aggregation Description
Most signal data is averaged. The field data_float_h.cnt describes the amount of values aggregated. It is to be expected that the first signal values have less than 60 data points, as it is quite unlikely (1:60) that signal starts on minute 0.
Raw values are saved in field data_float_h.rawdata, being a list of bytes. (IEEE 754 Single(4 bytes), LittleEndian) <noinclude> The recommended way to access this data is using our provided software ([[Get Started]]). An example on how to deserialize the raw_data field can be found [[Deserialize Raw Data|here]]. </noinclude> Metavision does, in database, not differentiate between qualitative (i.e. blood pressure) and quantitative (i.e. drainage volume) data, this was done programatically saving the sum instead of average.