Difference between revisions of "Medication Data"
(Created page with "== Data Description == The medication table contains data == Predefined Fields (RoDataServer) == == Known Limitations == The medication data is generally considered as being widely valid. Nevertheless there are some limitations to be stated: === Offsets and Times === The offset is the documented time of drug application. As the observed intensive care unity do not use perfusor telemetry all values are entered manually. Following inaccuracies of of time give may be...") |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
== Data Description == | == Data Description == | ||
{{:Data Description Medication}} | |||
== Predefined Fields (RoDataServer) == | == Predefined Fields (RoDataServer) == | ||
Line 18: | Line 18: | ||
The difference is explained in different default view range in medication input forms. | The difference is explained in different default view range in medication input forms. | ||
=== Different Reference for similar drugs === | |||
Due to liberal laws concerning drug names in Austria not all drugs are correctly labeled by their INN name and sometimes multiple proprietary products for the same substance are used. The SICDB Team used an algorithm to identify and unify the medication data. There may be special cases where this procedure failed, for example at compound antihypertensive drugs. |
Latest revision as of 09:11, 1 November 2022
Data Description
Contains all medication given during stay. Additional data like name and unit of measurement is found in d_references, where medication.DrugID is associated to d_references.ReferenceGlobalID. Metavision does not differ between continuous or single doses in rangesignals, so a single dose is set to 60 second admission time. Each change of a continuous application will end the current entry and create a new one.
Name | Type | Description | Comment |
---|---|---|---|
id | Integer | Primary Key | |
CaseID | Integer | Case identifier | |
DrugID | Reference | ||
Offset | Integer | Time in seconds after admission | |
OffsetDrugEnd | Integer | If drug was given continuously refers to end of application. Field is set to 60 seconds on bolus application. | |
IsSingleDose | Integer | Set to 1 when given as bolus. | |
Amount | Float | Full amount given regardless of time | Unity of measurement found in d_references |
AmountPerMinute | Float | Dosage per minute | Unity of measurement found in d_references |
Predefined Fields (RoDataServer)
Known Limitations
The medication data is generally considered as being widely valid. Nevertheless there are some limitations to be stated:
Offsets and Times
The offset is the documented time of drug application. As the observed intensive care unity do not use perfusor telemetry all values are entered manually. Following inaccuracies of of time give may be generally expected:
- +/- 5 minutes in anaesthesia settings
- +/- 5 minutes in resuscitation settings
- +/- 15 minutes in intensive care settings
The difference is explained in different default view range in medication input forms.
Different Reference for similar drugs
Due to liberal laws concerning drug names in Austria not all drugs are correctly labeled by their INN name and sometimes multiple proprietary products for the same substance are used. The SICDB Team used an algorithm to identify and unify the medication data. There may be special cases where this procedure failed, for example at compound antihypertensive drugs.